Price
Request a Quote
Stock
Out of Stock

  • Range - ± 100 G
  • Cable Length - 36 Custom Length: Inches
  • Calibration - 2 Vdc

Specifications

Accuracy

  • ± 1 % of Full Scale - Non-Linearity

Applications

  • Crash Testing
  • Crush Zone Testing
  • Impact Testing
  • Off-Road Testing
  • Transportation Testing

Approvals & Certifications

  • CE
  • RoHS

Cable Length

  • 30 ft (9.14 m)

Cable Material

  • PFA

Electrical Connectors

  • 28 AWG Conductors

Environmental Protection

  • IP65

Excitation Voltage

  • 2-10 Vdc

Frequency

  • 0 to 3,000 Hz
  • 7,000 Hz

Insulation Resistance

  • > 100 MΩ at 50 Vdc

Mounting

  • Adhesive

NACE & NIST

  • NIST

Operating Temperature

  • -20° to 85° C (-4° to 185° F)

Output

  • < ± 40 mV - Zero Acceleration Output
  • ± 40 mV - Zero Measured Output

Resistance

  • 2,400 to 6,000 ohms

Seat / Seal Material

  • Epoxy Sealed

Sensitivity

  • < 3 % - Transverse Sensitivity
  • ± 0.2 %/°C - Thermal Sensitivity Shift
  • 0.15 to 2 mV/g

Shock

  • 3,000 to 5,000 G

Temperature Range

  • 0° to 50° C (32° to 120° F)

Thermal Drift

  • ± 0.05 % of Full Scale/°C - Thermal Zero Shift

show more