  • Model - 17
  • Pressure Range - 0 to 50 psig
  • Pressure Type - Gauge

Specifications

Ambient Temperature Range

  • 25° C (77° F)

Applications

  • Altitude Measurement
  • Factory Automation
  • Handheld Calibrators
  • Medical Instruments
  • Process Control
  • Vacuum Measurement

Approvals & Certifications

  • RoHS

Compensated Temperature

  • -20° to 85° C (-4° to 185° F)

Frequency

  • 10 to 1,000 Hz

Hysteresis

  • ± 0.01 % of Span

Linearization

  • ± 0.1 % Non-Linearity

Media

  • Non-Corrosive Dry Gases Compatible with Silicon, Pyrex, RTV, Gold, Nickel, & Aluminum

Operating Temperature

  • -40° to 125° C (-40° to 257° F)

Output

  • ± 1.0 mV
  • ± 2 mV - Zero Pressure Output

Output Noise

  • 1 µV Peak-to-Peak

Power Requirement

  • 1.5 mA - Supply Current

Pressure Range

  • psig: 0 to 250 (kPa: 0 to 1,724, bar: 0 to 17.24)

Pressure Type

  • Absolute
  • Gauge

Resistance

  • 2,200 to 5,800 ohms - Input
  • 4,200 ohms - Output

Response Time

  • 1 ms - 10 to 90 %

Sensitivity

  • ± 1 % Interchangeability

Stability

  • ± 0.05 % of Span

Storage Temperature

  • -50° to 150° C (-58° to 302° F)

show more