Price
Request a Quote
Stock
Out of Stock

  • Pressure Type - Gauge Pressure
  • Pressure Range - 0 to 100 psi
  • Electrical Connection - Cable w/ Connector

Specifications

Applications

  • Fresh & Waste Water Measurements
  • Medical Instruments
  • Partial Vacuum Gas Measurement
  • Pressure Transmitter
  • Process Control
  • Tank Level Systems (RV & Industrial)

Approvals & Certifications

  • RoHS

Compensated Temperature

  • -20° to 85° C (-4° to 185° F)

Current

  • 0.5-2 mA - Supply Current

Diaphragm Material

  • 316L Stainless Steel

Enclosure, Body Material

  • 316L Stainless Steel

Hysteresis

  • ± 0.2 % of Span - Pressure Hysteresis
  • ± 0.25 % of Span - Thermal Hysteresis: Span & Offset

Insulation Resistance

  • 50 MΩ at 50 Vdc

Media

  • Liquids & Gases Compatible with 316, 316L Stainless Steel

Mounting

  • O-Ring

Operating Temperature

  • -40° to 105° C (-40° to 221° F)

Output

  • ± 1 mV - Zero Pressure Output, Offset

Output Load

  • 5 MΩ - Output Load Resistance

Output Noise

  • 1 µV Peak-to-Peak

Pressure Range

  • bar: 0 to 20.68
  • kPa: 0 to 2,068
  • psig: 0 to 300

Pressure Type

  • Absolute
  • Gauge

Repeatability

  • ± 0.02 % of Span

Resistance

  • 2 to 5.8 kΩ - Input Resistance
  • 3 to 25 kΩ - Output Resistance

Response Time

  • 0.1 ms

Span - Minimum

  • 75-150 mV - Span

Span & Zero Effect

  • ± 1 % of Span - Temperature Error - Span & Zero

Stability

  • ± 0.10 % of Span/Year - Long Term Stability-Span & Offset

Storage Temperature

  • -50° to 105° C (-58° to 221° F)

show more