  • Model - 30 bar White Gel High Endurance - Tube Delivery Form

Specifications

Accuracy

  • ± 0.8° C (± 1.4° F)

Ambient Temperature Range

  • 25° C (77° F)

Approvals & Certifications

  • RoHS

Communication

  • 16-bit - Analog to Digital Converter
  • 3-Wire Serial Interface

Consumption

  • 0.5 µA - Current Consumption Into MCLK

Duty Cycle

  • 40 to 60 % - Duty Cycle of MCLK

Frequency

  • 30 to 500 KH - External & Serial Data Clock (MCLK & SCLK)

Input

  • 0-20 % Vdd - Input & Output Low Voltage
  • 80-100 % Vdd - Input & Output High Voltage

Media

  • Non-Corrosive Dry Gases

Operating Temperature - Sensor

  • -40° to 85° C (-40° to 185° F)

Output

  • 0.1 µA at 3 Vdd - Max.
  • 1 mA at 3 Vdd - Typical Supply Current (During Conversion)
  • 4 µA at 3 Vdd - Typical Supply Current (Average)

Overpressure & Static Pressure Limits

  • psi: 725.2 (kPa: 5,000, bar: 50) - Overpressure

Pressure Range

  • bar: 0 to 30
  • kPa: 0 to 3,000
  • psi: 0 to 435.1

Pressure Type

  • Absolute

Resolution

  • 0.005° to 0.015° C
  • 16-bits
  • 3 Mbar

Response Time

  • 35 ms - Conversion Time

Sensitivity

  • 4 kV - ESD Sensitivity

Sensor, Probe Material

  • Silicon - Piezoresistive

Sensor, Probe Type

  • Pressure Sensor - Integrated Miniature

Stability

  • 50 Mbar Per Year - Long Term Stability

Storage Temperature

  • -40° to 85° C (-40° to 185° F)

Supply Voltage

  • 2.2-3.6 V

show more