Model XPDH Differential Pressure Transducer

Brand: Tecsis

This high range differential (delta) pressure transducer covers ranges from 0 to 2,000 to psi: 0 to 10,000 (kPa: 0 to 68,948, bar: 0 to 689.5). 

Rugged, all-welded stainless steel construction makes this bi-directional wet/wet unit the best choice for demanding applications.

 Standard output is 2 mV/V, and an internally amplified version is available. 

Reliable strain gage technology provides a combined 0.25% Full ScaleO accuracy. 

Various pressure ports and electrical connections are offered.
Features
  • High differential pressure
  • All stainless construction
  • Wide operating temperature

Models matching criteria: 5
  • Capacity - 5,000 psid
Out of Stock
Does not ship to OH, United States
  • Capacity - 3,000 psid
Out of Stock
Does not ship to OH, United States
  • Capacity - 10,000 psid
Out of Stock
Does not ship to OH, United States
  • Capacity - 2,500 psid
Out of Stock
Does not ship to OH, United States
  • Capacity - 2,000 psid
Out of Stock
Does not ship to OH, United States

Specifications

Brand

Approvals & Certifications

  • ISO 9001: 2015 Certified

Compensated Temperature

  • 16° to 71° C (60° to 160° F)

Differential Pressure

  • psid: 0 to 10,000 (kPa: 0 to 68,950, bar: 0 to 689.5)

Electrical Connectors

  • Bendix PTIH-10-6P

Enclosure, Body Material

  • Stainless Steel

Excitation Voltage

  • 10 Vdc
  • 15 Vdc, Max.

Hysteresis

  • ± 0.25 % of FSO, Combined

Line Pressure

  • Maximum

Linearity

  • ± 0.25 % of FSO, Combined

Operating Temperature

  • -54° to 120° C (-65° to 250° F)

Output

  • 2 mV/V

Overpressure & Static Pressure Limits

  • Maximum

Pressure Range

  • bar: 0 to 689.5
  • kPa: 0 to 68,948
  • psi: 0 to 10,000

Pressure Type

  • Differential

Repeatability

  • ± 0.05 % of FSO

Resistance

  • Bridge Resistance: 350 ohms

Span & Zero Effect

  • Span Effect: ± 0.5 % of Reading at 38° C (100° F)
  • Zero Effect: ± 0.5 % of FSO at 38° C (100° F)

Wetted Materials

  • Stainless Steel

Zero Balance

  • ± 1 % of FSO

show more