Accuracy
- ± 0.1 % of Full Scale
- 0.2%
Approvals & Certifications
- EN
- ISO 9001: 2015 Certified
- SIL 3 Certification
Approvals & Certifications
- ATEX
- CSA
- EMC According to Directive EN 61326
- FM
- IEC Ex
- TÜV-Sud- No. Z-IS-ATA3-MAN 6000219499 According to EN 62061: 2005
- UL
Consumption
- Power Consumption Relay: Approximately 100 mW
Electrical Connectors
- Circular Connector 4-Pin M12 x 1 - F2301
Electrical Protection
- Overvoltage
- Reverse Polarity Voltage
- Short Circuit Protected
Environmental Protection
- IP67 (According to EN 60529 / IEC 529)
Hysteresis
- ≤ ± 0.1 % of Full Scale Cn
Load Limit
- 150 % Fnom
- Breaking Load: > 300 % Fnom
Materials of Construction
- Material Counter Nut: Nickel-Plated Steel - F2301
Measuring Error
- Combined Error: ≤ ± 0.2 % of Full Scale
Measuring Range
- Tension & Compression Forces from 1 to 100 KN
Output
- Analog Output: 0-7 V, 3-Wire - F23C1 SIL 3
- Analog Output: 4-16 mA, 2-Wire - F23C1 SIL 3
- Analog Output: 4-20 mA, 2-Wire - F2301
- Maximum
- Voltage Output: Approximately 8 mA - F2301, F23C1 SIL 3
Power Requirement
- 10-30 Vdc for Current Output - F2301
- 14-30 Vdc for Voltage Output - F2301
Power Supply
- Relay Power Supply: 24 V, Max.
Response Time
- ≤ 1 ms (within 10 % to 90 %) - F2301
- ≤ 5 ms (within 10 % to 90 %) - F23C1 SIL 3
Service Temperature
- -40° to 80° C (-40° to 176° F)
Span & Zero Effect
- ≤ ± 0.2 % of Full Scale/10K
Storage Temperature
- -40° to 85° C (-40° to 185° F)
Temperature Effect
- Span & Zero: ≤ ± 0.2 % of Full Scale/10K
Temperature Range
- Nominal -20° to 80° C (-4° to 176° F)
Vibration
- 20 G, 100h, (50 to 150 Hz) According to DIN EN 60068-2-6