Model ILA5/10/ILA420-3W/ILA5 In-Line Amplifier

Brand: Tecsis

External or in-line amplifiers are available for all types of load and pressure sensors and are valuable when an amplified signal is needed but the conditions do not allow an internal amplifier to be used. 

Miniature load cells or pressure sensors often do not have room for an internal amplifier. 

Also, internal amplifiers can be damaged if the sensor is to be used in an application where the temperature exceeds 300° F. 

In those cases, the amplifier can be located away from the sensor in an area with a more hospitable ambient temperature.

Models matching criteria: 4
Out of Stock
Does not ship to OH, United States
  • Current Draw - 30 mA
Out of Stock
Does not ship to OH, United States
  • Current Draw - 85 mA
Out of Stock
Does not ship to OH, United States
  • Current Draw - 50 mA
Out of Stock
Does not ship to OH, United States

Specifications

Brand

Approvals & Certifications

  • ISO 9001: 2015 Certified

Approvals & Certifications

  • CE

Channels

  • 1

Current

  • ILA10: 50 mA
  • ILA420-3W: 85 mA
  • ILA5: 30 mA
  • ILA5-BP / ILA10-BP: 70 mA
  • Output Current ILA5, ILA10, ILA5-BP / ILA10-BP: 2 mA - Max.

Enclosure, Body Material

  • Plastic

Environmental Protection

  • Sealing: IP66
  • Sealing: NEMA 4

Excitation Voltage

  • Transducer Excitation: 2.5 or 5 Vdc at 30 mA - ILA5
  • Transducer Excitation: 2.5, 5 or 10 Vdc at 50 mA - ILA10
  • Transducer Excitation: 2.5, 5 or 10 Vdc at 70 mA - ILA5-BP / ILA10-BP
  • Transducer Excitation: 2.5, 5 or 10 Vdc at 85 mA - ILA420-3W

Linearity

  • ± 0.02 % of Full Scale

Mounting

  • 6 or 8 Screw Mount
  • Panel Mount

Operating Temperature

  • ILA5, ILA10, ILA420-3W: -15° to 50° C (5° to 122° F)
  • ILA5-BP / ILA10-BP: -28.8° to 70° C (-20° to 158° F)

Output

  • ILA10, ILA5-BP / ILA10-BP: ± 10 Vdc
  • ILA420-3W: 4-20 mA, 3-Wire
  • ILA5, ILA5-BP / ILA10-BP: ± 5 Vdc

Output Noise

  • DC Power Supply Rejection Ratio: > 110 dB
  • Signal to Noise Ratio: 65 dB

Span & Zero Adjustments

  • Span & Zero Adjustment Coarse, Fine: ± 25 %
  • Span Adjustment Coarse: 0.5-5 mV/V - ILA5
  • Span Adjustment Coarse: 0.5-6.6 mV/V - ILA420-3W, ILA5-BP / ILA10-BP
  • Span Adjustment Coarse: 1-20 mV/V - ILA10
  • Zero Adjustment Coarse: ± 50 % - ILA5, ILA5-BP / ILA10-BP
  • Zero Adjustment Coarse: ± 70 % - ILA420-3W
  • Zero Adjustment Fine: ± 10 % - ILA10
  • Zero Adjustment Fine: ± 15 % - ILA5, ILA5-BP / ILA10-BP

Supply Voltage

  • ILA10, ILA420-3W: 18-32 Vdc
  • ILA5: 11-28 Vdc
  • ILA5-BP / ILA10-BP: ± 15 Vdc
show more