Model XPIH-1U High Pressure Industrial Transducer

Brand: Tecsis

High pressure applications require a pressure transducer with the ability to handle extremes in both pressures and fixturing. 

With an integral high pressure fitting, fully welded construction and a wide operating temperature, the Model XPIH is built to survive. 

This unit is available with mV/V, 0-5V or 4-20 mA output and standard accuracy of ±0.25% Full ScaleO (±0.10% optionally available). 

Designed for high ranges from 0 to 15,000 to psi: 0 to 60,000 (kPa: 0 to 413,685, bar: 0 to 4,137) this robust unit will withstand the rigors and temperatures associated with high pressure conditions. 

Available with zero and span pots (amplified version only) and a variety of pressure connections and electrical terminations to fit your application.
Features
  • Very high capacities available
  • Integral high pressure fitting
  • All stainless construction
  • Wide operating temperature
  • High accuracy

Specifications

Brand

Accuracy

  • ± 0.1 % of FSO
  • ± 0.25 % of FSO

Approvals & Certifications

  • ISO 9001: 2015 Certified

Burst Pressure

  • 170 % of Rated Pressure

Compensated Temperature

  • 15° to 71° C (60° to 160° F)

Electrical Connectors

  • Bendix PTIH-10-6P

Excitation Voltage

  • 10 Vac/dc (15 V, Max.

Hysteresis

  • ± 0.05 % of FSO

Linearity

  • ± 0.1 % of FSO
  • ± 0.25 % of FSO

Materials of Construction

  • 630 Stainless Steel (17-4 PH)

Operating Temperature

  • -73° to 163° C (-100° to 325° F)

Output

  • 2 mV/V ± 0.25 %
  • 3 mV/V Optional

Pressure Range

  • bar: 0 to 4,137
  • kPa: 0 to 413,685
  • psi: 0 to 60,000

Pressure Type

  • Gauge

Proof Pressure

  • 125 % of Rated Pressure

Repeatability

  • ± 0.05 % of FSO

Resistance

  • Input Resistance: 360 ohms Min.
  • Output Resistance: 350 ± 5 ohms

Span & Zero Effect

  • Span Effect of High Accuracy: ± 0.0025 % of Reading/°F
  • Span Effect of Standard Accuracy: ± 0.005 % of Reading/°F
  • Zero Effect of High Accuracy: ± 0.0025 % of FSO/°F
  • Zero Effect of Standard Accuracy: ± 0.005 % of FSO/°F

Wetted Materials

  • 630 Stainless Steel (17-4 PH)

Zero Balance

  • ± 1 % of FSO
show more