Accuracy
- Carbon Dioxide (Infrared): ± 0.5 % Volume
- Carbon Monoxide Corrected CO: Calculated
- Carbon Monoxide, Oxygen O₂ (Fuel Cell), Hydrocarbon (HC-hexane) (NDIR), Carbon Dioxide (Infrared): ± 5 % of Reading
- Carbon Monoxide: ± 0.06 % Volume
- Hydrocarbon (HC-hexane) (NDIR): ± 12 ppm Volume
- Nitric Oxide (Fuel Cell): 0-4000 ppm ± 4 % or 25 ppm
- Nitric Oxide (Fuel Cell): 4000 - 5000 ppm ± 5 %
- Oil Temperature: ± 2.0° C ± 0.3 % of Reading
- Oil Temperature: ± 3.6° F ± 0.3 % of Reading
- Oxygen O₂ (Fuel Cell): ± 0.1 % Volume
- RPM: 50 rpm
Ambient Operating Range
- +5° to +40° C / 10 to 90 % RH, Non-Condensing
Analyser Battery Run Time
- > 4 Hours from Full Charge with the Pump Running
Battery Charger
- Input: 110 VAC/230 VAC Nominal
- Output: 10 VAC Off Load
Range
- Carbon Dioxide (Infrared): 0 - 16 %
- Carbon Dioxide (Infrared): Over-Range 25 %
- Carbon Monoxide Corrected CO: 0 - 15 %
- Carbon Monoxide: 0 - 10 %
- Carbon Monoxide: Over-Range 20 %
- Hydrocarbon (HC-hexane) (NDIR): 0-3000 ppm
- Hydrocarbon (HC-hexane) (NDIR): Over-Range 10,000 ppm
- Lambda AFR (Petrol) (LPG): 0.8 - 1.2
- Lambda AFR (Petrol) (LPG): 11.76 - 17.64
- Lambda AFR (Petrol) (LPG): 12.48 - 18.72
- Nitric Oxide (Fuel Cell): 0 - 5000 ppm
- Oil Temperature: 0° C - 150° C (32° to 302° F)
- Oxygen O₂ (Fuel Cell): 0 - 21 %
- Oxygen O₂ (Fuel Cell): Over-Range 48 %
- RPM: 200 - 6,000 rpm
Resolution
- Carbon Monoxide, Oxygen O₂ (Fuel Cell), Carbon Monoxide Corrected CO: 0.01 %
- Hydrocarbon (HC-hexane) (NDIR), Carbon Dioxide (Infrared), Nitric Oxide (Fuel Cell): 1 ppm
- Lambda AFR (Petrol) (LPG): 0.001
- Lambda AFR (Petrol) (LPG): 0.01
- Oil Temperature: 1.0° C/F
- RPM: 1 rpm
Sensor, Probe
- Clip Handle to Secure to Exhaust, 4 m Long Hose
- Insertion Depth 350 mm x Diameter 15 mm
- Various Probes Available Including High Temperature