XLT2-0125-025K

Series: Model XLT Tension Link Load Cell Brand: Tecsis
Price
Request a Quote
Stock
Out of Stock

  • Capacity - 25,000 lbs

Specifications

Brand

Approvals & Certifications

  • ISO 9001: 2015 Certified

Compensated Temperature

  • -20° to 70° C (-4° to 158° F)

Electrical Connectors

  • Bendix PTIH-10-6P
  • Integral Cable

Electrical Protection

  • Overload Protection

Enclosure, Body Material

  • 630 Stainless Steel (17-4 PH)

Excitation Voltage

  • 9-15 Vdc

Hysteresis

  • ± 0.25 % of FSO, Combined

Linearity

  • ± 0.25 % of FSO, Combined

Load

  • Safe Overload: 150 % of Capacity

Measuring Range

  • 0 to 100,000 lb

Operating Temperature

  • -40° to 125° C (-40° to 260° F)

Output

  • 2 mV/V Nominal

Repeatability

  • ± 0.25 % of FSO, Combined

Resistance

  • Bridge Resistance: 350 ohms

Span & Zero Effect

  • ± 0.75 % of FSO

show more