Accuracy
- Carbon Dioxide (Infrared): ± 0.5 % Volume
- Carbon Monoxide (Infrared): ± 0.06 % Volume
- Carbon Monoxide Corrected COK: Calculated
- Carbon Monoxide, Carbon Dioxide, Hydrocarbon (Infrared) & Oxygen (Fuel Cell): ± 5 % of Reading
- Hydrocarbon (Infrared): ± 12 ppm Volume
- Nitric Oxide (Fuel Cell): 0-1500 ppm ± 5 % or 25 ppm
- Oxygen (Fuel Cell): ± 0.1 % Volume
Ambient Operating Range
- +5° to +45° C / 10 % to 90 % RH, Non-Condensing
Analyser Battery Run Time
- > 4 Hours from Full Charge with the Pump Running
Battery Charger
- Input: 100-240 V ~ 47-63 Hz
- Output: 12 Vdc
Pre-Programmed Fuels
- Petrol/Gasolene, LPG Diesel & CNG
Range
- Carbon Dioxide (Infrared): 0-16 %
- Carbon Dioxide (Infrared): Over-Range 25 %
- Carbon Monoxide (Infrared): 0-10 %
- Carbon Monoxide (Infrared): Over-Range 20 %
- Carbon Monoxide Corrected COK: 0-15 %
- Hydrocarbon (Infrared): 0-5000 ppm
- Hydrocarbon (Infrared): Over-Range 10,000 ppm
- Lambda AFR (Petrol) (LPG): 0.8 - 1.2
- Lambda AFR (Petrol) (LPG): 11.76 - 17.64
- Lambda AFR (Petrol) (LPG): 12.48 - 18.72
- Nitric Oxide (Fuel Cell): 0-1500 ppm
- Nitric Oxide (Fuel Cell): Over-Range 5000 ppm
- Oxygen (Fuel Cell): 0-21 %
- Oxygen (Fuel Cell): Over-Range 25 %
Resolution
- Carbon Dioxide (Infrared): 0.1 %
- Carbon Monoxide (Infrared), Oxygen (Fuel Cell), Carbon Monoxide Corrected COK: 0.01 %
- Hydrocarbon (Infrared), Nitric Oxide (Fuel Cell): 1 ppm
- Lambda AFR (Petrol) (LPG): 0.001
- Lambda AFR (Petrol) (LPG): 00.01
Sensor, Probe
- Clip Handle to Secure to Exhaust, 4 M Long Hose
- Insertion Depth 350 mm x Diameter 15 mm
- Various Probes Available Including High Temperature